• <tr id='wRiChY'><strong id='wRiChY'></strong><small id='wRiChY'></small><button id='wRiChY'></button><li id='wRiChY'><noscript id='wRiChY'><big id='wRiChY'></big><dt id='wRiChY'></dt></noscript></li></tr><ol id='wRiChY'><option id='wRiChY'><table id='wRiChY'><blockquote id='wRiChY'><tbody id='wRiChY'></tbody></blockquote></table></option></ol><u id='wRiChY'></u><kbd id='wRiChY'><kbd id='wRiChY'></kbd></kbd>

    <code id='wRiChY'><strong id='wRiChY'></strong></code>

    <fieldset id='wRiChY'></fieldset>
          <span id='wRiChY'></span>

              <ins id='wRiChY'></ins>
              <acronym id='wRiChY'><em id='wRiChY'></em><td id='wRiChY'><div id='wRiChY'></div></td></acronym><address id='wRiChY'><big id='wRiChY'><big id='wRiChY'></big><legend id='wRiChY'></legend></big></address>

              <i id='wRiChY'><div id='wRiChY'><ins id='wRiChY'></ins></div></i>
              <i id='wRiChY'></i>
            1. <dl id='wRiChY'></dl>
              1. <blockquote id='wRiChY'><q id='wRiChY'><noscript id='wRiChY'></noscript><dt id='wRiChY'></dt></q></blockquote><noframes id='wRiChY'><i id='wRiChY'></i>

                EP6000 series electrical and gas valve locator

                Products > Valve positioner > EP6000 series electrical and gas valve locator

                EP6000 series electrical and gas valve locator

                1, Suitable for small capacity and large capacity of actuators.
                2, Amplifier, gas consumption is small, large capacity.
                3, Can choose the output characteristic.
                4, Single-acting actuator in need reaction control, positive action type amplifier is
                easy to transform into a reaction type amplifier.
                5, Pressure explosion-proof type can be adjusted in the field.
                6, Intrinsically safe has a broad scope of the structure of the building.
                Contact purchase

                Share

                First, Product Overview
                EP6000 series of electric valve positioner and actuator, 4 ~ 20 mA DC input the  signal output of air pressure, the control action of the actuator. At the same time  according to the stroke of the actuator feedback, so that the actuator stroke can  accurate positioning according to control signal. EP6000 series electric valve  positioner can be used for single action and double action type actuator.

                Second, Technical Data

                SeriesEP6000
                Input signal4-20mA DC
                Process control can be carried out
                Adjustment range:4-12、12-20mA DC
                Input impedance250Ω~±5% at 25℃
                Output characteristicLinear (standard)
                AmplifierSingle action type actuator and double action type actuator combination, single action is action type
                amplifier is easy to transform into a reaction type amplifier (input signal increases, the output pressure decreases).
                Air pressure0.14-0.7MPa(140-700KPa)
                Output pressure0-0.7MPa(0-700KPa)
                Air consumptionThe output 50% air pressure gas consumption.
                Single acting type:  5NI/min at 140KPa air supply
                Double acting type:  15NI/min at 400KPa air supply
                The biggest processing capacityWhen the output side air vent
                Single acting type:175NI/min at 140KPa air supply
                Double acting type:400NI/min at 400KPa air supply
                PerformanceSingle action type actuator
                Linearity ................±1.0% of Full stroke
                Hysteresis ................0.5%of Full stroke
                Response ................0.1% of Full stroke
                Repeat accuracy .............0.2% of Full stroke
                Air pressure change of error ....0.1% /10KPa
                Double action type actuator
                Linearity ................±1.5% of Full stroke
                Hysteresis ................0.8% of Full stroke
                Response ................0.2% of Full stroke
                Repeat accuracy.............0.3% of Full stroke
                Air pressure change of error ....0.4%/10KPa
                The above represents the performance of the positioner on an actuator without a valve.
                Air supply connectionRC1/4
                Power interfaceNPT1/2(G1/2)
                Environment temperatureStandard type:-20~80℃
                Humidity range10~90%RH
                Structure formOutdoor waterproof type (increased safety type) e Ex eⅡT6 Gb,IP65
                Pressure explosion-proof (flameproof type)d Ex dⅡBT6 Gb
                Intrinsically safe type (intrinsic safety type)i Ex iaⅡCT6 Gb
                Subsidiary bodyAuto,Manual change
                Shell materialAluminum alloy
                Surface coatingSpray plastic
                Standard coating colorBlack  Lightgray  Blue
                Weight2.3Kg-3Kg
                Additional specificationsAccording to the customer request production
                Electrical interface1/2NPT (Outdoor waterproof type)
                Pressure filler type (Pressure explosion-proof type)
                Seal joint type (Pressure explosion-proof type)
                Safety barrierZener safety barrier(Ex iaⅡC)
                Pressure gauge calibrationMPa、KPa、Bar、Psi
                CharacteristicEqual percentage
                Air interface1/4NPT


                Third, Model Specification

                EP6   0     0     0     0     0   

                ModelExplosion-proof grade
                (protection) structure
                Feedback (action)Action typeAccessories
                EP6 1 Flame proof d Ex
                dⅡBT6 Gb
                 1   Straight travel actuators:standard
                 1 Single action with
                actuator (single-acting)
                 b    AS  
                With correlation
                matching combination
                Air filtering pressure
                reducing valve
                 2 Increased safety type
                e Ex d ⅡT6 Gb, IP65
                 2 Quarter-turn
                actuators:standard
                 2 Double action with
                actuator(double-acting)
                 3 Intrinsic safety type
                I Ex iaⅡC T6 Gb


                  

                Example: EP3111: said flameproof, straight trip, single function
                EP3322: it means the Ann model, Angle, dual role

                When ordering, please specify: 1, Type;  2, Input signal;  3, Gas supply pressure;  4, Output characteristic;  5, With pressure reducer;
                6, Stroke;  7, The actuator specifications;  8, Output pressure.